National Repository of Grey Literature 10 records found  Search took 0.01 seconds. 
Development of an Algorithm for Automatic Characterization of a Sample Based on the Data Received by Means of the Laser Induced Breakdown Spectroscopy (LIBS).
Klus, Jakub ; Černohorský,, Tomáš (referee) ; Veis,, Pavel (referee) ; Kaiser, Jozef (advisor)
Submitted work concerns with the theoretical and practical requirements for an automatic characterization of samples by means of Laser-Induced Breakdown Spectroscopy (LIBS). Theoretical aspects of laser-matter interaction, plasma expansion, and plasma emission are described theoretically within this work. The description of the plasma emission is enhanced with the spectral detection systems and statistical properties of the plasma. The principle of the automatic characterization is based on the multivariate data analysis theoretical background, which presents recent trend and fundamental approach for automatic spectra analysis in LIBS. Theoretical knowledge is manifested in six applications, which are presented as a comment to published manuscripts. These publications push the frontiers of automatic spectra processing in LIBS.
Using Laser-Induced Breakdown Spectroscopy (LIBS) for Material Analysis
Pořízka, Pavel ; Hrdlička, Aleš (referee) ; Pína,, Ladislav (referee) ; Kaiser, Jozef (advisor)
Tato doktorská práce je zaměřena na vývoj algoritmu ke zpracování dat naměřených zařízením pro spektrometrii laserem indukovaného plazmatu (angl. LIBS). Zařízení LIBS s tímto algoritmem by mělo být následně schopno provést třídění vzorků a kvantitativní analýzu analytu in-situ a v reálném čase. Celá experimentální část této práce byla provedena ve Spolkovém institutu pro materiálový výzku a testování (něm. BAM) v Berlíně, SRN, kde byl sestaven elementární LIBS systém. Souběžně s experimentílní prací byl vytvořen přehled literárních zdrojů s cílem podat ucelený pohled na problematiku chemometrických metod používaných k analýze LIBS měření. Použití chemometrických metod pro analýzu dat získaných pomocí LIBS měření je obecně doporučováno především tehdy, jsou-li analyzovány vzorky s komplexní matricí. Vývoj algoritmu byl zaměřen na kvantitativní analýzu a třídění vyvřelých hornin na základě měření pomocí LIBS aparatury. Sada vzorků naměřených použitím metody LIBS sestávala z certifikovaných referenčních materiálů a vzorků hornin shromážděných přímo na nalezištích mědi v Íránu. Vzorky z Íránu byly následně na místě roztříděny zkušeným geologem a množství mědi v daných vzorcích bylo změřeno na Univerzitě v Clausthalu, SRN. Výsledné kalibrační křivky byly silně nelineární, přestože byly sestaveny i z měření referenčních vzorků. Kalibrační křivku bylo možné rozložit na několik dílčích tak, že závislost intenzity měděné čáry na množství mědi se nacházela v jiném trendu pro jednotlivé druhy hornin. Rozdělení kalibrační křivky je zpravidla přisuzováno tzv. matričnímu jevu, který silně ovlivňuje měření metodou LIBS. Jinými slovy, pokud určujeme množství analytu ve vzorcích s různou matricí, je výsledná kalibrační křivka sestavená pouze z jedné proměnné (intenzity zvolené spektrální čáry analytu) nepřesná. Navíc, normalizace takto vytvořených kalibračních křivek k intenzitě spektrální čáry matrčního prvku nevedla k výraznému zlepšení linearity. Je obecně nemožné vybrat spektrální čáru jednoho matričního prvku pokud jsou analyzovány prvky s komplexním složením matric. Chemometrické metody, jmenovitě regrese hlavních komponent (angl. PCR) a regrese metodou nejmenších čtverců (angl. PLSR), byly použity v multivariační kvantitatvní analýze, tj. za použití více proměnných/spektrálních čar analytu a matričních prvků. Je potřeba brát v potaz, že PCR a PLSR mohou vyvážit matriční jev pouze do určité míry. Dále byly vzorky úspěšně roztříděny pomocí analýzy hlavních komponent (angl. PCA) a Kohonenových map na základě složení matričních prvků (v anglické literatuře se objevuje termín ‚spectral fingerprint‘) Na základě teorie a experimentálních měření byl navržen algoritmus pro spolehlivé třídění a kvantifikaci neznámých vzorků. Tato studie by měla přispět ke zpracování dat naměřených in-situ přístrojem pro dálkovou LIBS analýzu. Tento přístroj je v současnosti vyvíjen v Brně na Vysokém učení technickém. Toto zařízení bude nenahraditelné při kvantifikaci a klasifikaci vzorků pouze tehdy, pokud bude použito zároveň s chemometrickými metodami a knihovnami dat. Pro tyto účely byla již naměřena a testována část knihoven dat v zaměření na aplikaci metody LIBS do těžebního průmyslu.
Lyme borreliosis diagnostics using in vitro cellular immune response testing
Prokopová, Tereza ; Drbal, Karel (advisor) ; Melter, Oto (referee)
Lyme borreliosis is a multisystemic disease affecting skin, joints, heart and central nervous system. The disease is caused by spirochetes of Borrelia burgdorferi sensu lato complex. These bacteria are spread by ticks of Ixodes genus. In 2016 there were almost 4,000 newly infected individuals reported in the Czech Republic. Contemporary serological diagnostics of Lyme borreliosis is not sensitive nor specific enough and does not even correlate with the pathology of the disease in the early or late phases. For the correct diagnosis of the disease it is necessary to detect the pathogen and its genotype. For this reason we had aimed at two goals. Through the digital droplet PCR (ddPCR) method we detected Borrelia-specific DNA and its genotype. The detection limit of borrelial DNA was set on gDNA samples isolated from the tick. Detection threshold for the initial amount of 1 ng of tick gDNA is at the range of 10-17 g of specific borrelial DNA. Borrelia spp. coinfection was detected in 5 out of 12 tested samples. The most frequent type was B. garinii which was detected in 5 samples. On the basis of published sequences for virulent factors we have designed specific primers in conserved regions of the genes flanking their variable segments to be PCR amplified. Gene variability will be monitored through...
Development of an Algorithm for Automatic Characterization of a Sample Based on the Data Received by Means of the Laser Induced Breakdown Spectroscopy (LIBS).
Klus, Jakub ; Černohorský,, Tomáš (referee) ; Veis,, Pavel (referee) ; Kaiser, Jozef (advisor)
Submitted work concerns with the theoretical and practical requirements for an automatic characterization of samples by means of Laser-Induced Breakdown Spectroscopy (LIBS). Theoretical aspects of laser-matter interaction, plasma expansion, and plasma emission are described theoretically within this work. The description of the plasma emission is enhanced with the spectral detection systems and statistical properties of the plasma. The principle of the automatic characterization is based on the multivariate data analysis theoretical background, which presents recent trend and fundamental approach for automatic spectra analysis in LIBS. Theoretical knowledge is manifested in six applications, which are presented as a comment to published manuscripts. These publications push the frontiers of automatic spectra processing in LIBS.
Using Laser-Induced Breakdown Spectroscopy (LIBS) for Material Analysis
Pořízka, Pavel ; Hrdlička, Aleš (referee) ; Pína,, Ladislav (referee) ; Kaiser, Jozef (advisor)
Tato doktorská práce je zaměřena na vývoj algoritmu ke zpracování dat naměřených zařízením pro spektrometrii laserem indukovaného plazmatu (angl. LIBS). Zařízení LIBS s tímto algoritmem by mělo být následně schopno provést třídění vzorků a kvantitativní analýzu analytu in-situ a v reálném čase. Celá experimentální část této práce byla provedena ve Spolkovém institutu pro materiálový výzku a testování (něm. BAM) v Berlíně, SRN, kde byl sestaven elementární LIBS systém. Souběžně s experimentílní prací byl vytvořen přehled literárních zdrojů s cílem podat ucelený pohled na problematiku chemometrických metod používaných k analýze LIBS měření. Použití chemometrických metod pro analýzu dat získaných pomocí LIBS měření je obecně doporučováno především tehdy, jsou-li analyzovány vzorky s komplexní matricí. Vývoj algoritmu byl zaměřen na kvantitativní analýzu a třídění vyvřelých hornin na základě měření pomocí LIBS aparatury. Sada vzorků naměřených použitím metody LIBS sestávala z certifikovaných referenčních materiálů a vzorků hornin shromážděných přímo na nalezištích mědi v Íránu. Vzorky z Íránu byly následně na místě roztříděny zkušeným geologem a množství mědi v daných vzorcích bylo změřeno na Univerzitě v Clausthalu, SRN. Výsledné kalibrační křivky byly silně nelineární, přestože byly sestaveny i z měření referenčních vzorků. Kalibrační křivku bylo možné rozložit na několik dílčích tak, že závislost intenzity měděné čáry na množství mědi se nacházela v jiném trendu pro jednotlivé druhy hornin. Rozdělení kalibrační křivky je zpravidla přisuzováno tzv. matričnímu jevu, který silně ovlivňuje měření metodou LIBS. Jinými slovy, pokud určujeme množství analytu ve vzorcích s různou matricí, je výsledná kalibrační křivka sestavená pouze z jedné proměnné (intenzity zvolené spektrální čáry analytu) nepřesná. Navíc, normalizace takto vytvořených kalibračních křivek k intenzitě spektrální čáry matrčního prvku nevedla k výraznému zlepšení linearity. Je obecně nemožné vybrat spektrální čáru jednoho matričního prvku pokud jsou analyzovány prvky s komplexním složením matric. Chemometrické metody, jmenovitě regrese hlavních komponent (angl. PCR) a regrese metodou nejmenších čtverců (angl. PLSR), byly použity v multivariační kvantitatvní analýze, tj. za použití více proměnných/spektrálních čar analytu a matričních prvků. Je potřeba brát v potaz, že PCR a PLSR mohou vyvážit matriční jev pouze do určité míry. Dále byly vzorky úspěšně roztříděny pomocí analýzy hlavních komponent (angl. PCA) a Kohonenových map na základě složení matričních prvků (v anglické literatuře se objevuje termín ‚spectral fingerprint‘) Na základě teorie a experimentálních měření byl navržen algoritmus pro spolehlivé třídění a kvantifikaci neznámých vzorků. Tato studie by měla přispět ke zpracování dat naměřených in-situ přístrojem pro dálkovou LIBS analýzu. Tento přístroj je v současnosti vyvíjen v Brně na Vysokém učení technickém. Toto zařízení bude nenahraditelné při kvantifikaci a klasifikaci vzorků pouze tehdy, pokud bude použito zároveň s chemometrickými metodami a knihovnami dat. Pro tyto účely byla již naměřena a testována část knihoven dat v zaměření na aplikaci metody LIBS do těžebního průmyslu.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.